Air conditioning, air works air conditioning in the room, mainly to lower room temperature, filter dust in the air and if necessary additional outdoor air into the room, ensure people living in the rooms are comfortable environment
1.Regularly clean mesh air filter. Typically, 2 to 3 times a week to clean, by washing as follows: Remove your face, draw a grid filter to grid filter under clean water and spray, mesh filter made of nilong, do not use hot water (above 40oC) for washing, and not dried (hot water wash and drying will be deformed, damaged). So dry the surface and then plugged into the computer again. 2.good defense to stop the trial heat of the cold block and radiator. The trial heat he made 0.15 mm aluminum tubes in the same cage. Very thin so it does not withstand the impact. If he rebels damaged aluminum kitchen is efficient to less heat and quieter environment, may affect the cooling effect, so pay attention to security. 3.defense system cooling, the cooling system filled with high gas cooling, if the damage components, or piping the cooling system leak caused the gas cooling air conditioners can not do cold. 4.Use fuse (or pressure factors in cool) properly by the technical criteria stated in the technical explanations of the machine). 5. The shutdown (or lose power) must wait two minutes after the newly opened computer if 2 minutes was not enough to open the machine balance the pressure of the system is not satisfactory. If at that time was booting the computer is not running, electric current increased greatly, will burn or jump voltage fuse shown in cool, harm or damage your air-conditioned temperature. 6.Summer after your operation, the temperature will be lowered quickly (less than 30oC). If after a long time that the temperature does not go down (below 30oC) so the machine will run long and easy to overload problems arise and your life will decrease. So in this case to find the cause why your room without running long, but lower temperatures, repair eliminate the cause of the phenomenon then used. Comments 7. Prevent moisture circuits, always in dry condition not wet, not leakage power, no mold section. 8.Plug, outlet to good, not loose. 9.Attention to strange sounds emanating from the free air conditioning, collision clack, cries of engine power or chassis for vibration ... must immediately stop the machine to find the cause, not fixed, when a strange language generated, to avoid more serious damage to machine. 10.Used in soft hair broom scanner parts at the end of an external dust. Per year for oil was a fan drive shaft. Ministry of cooling without scanning process just brush dust outside. 11.Machine with water cooling when machine running water valve is not closed. How to scan 1 to 2 months for air conditioning with dust in the wind outside. In winter, cold in origin to drop out of the water pipe cooling water precautions as cracked pipes freeze and damage the machine. By vocational